(+971) 4 210 2999

Fire Fighting

HFC-227EA CLEAN AGENT

Features

  • FM-200 also commonly known as HFC-227ea, is a clean agent fire suppressant.
  • Clean agents are fast and effective in suppressing fires, are safe in occupied spaces and do not leave a residue.

STORAGE CYLINDER

Features

  • Multiple series of containers are available including:
  • 16.6, 28.3, 40, 50, 60, 70, 80, 90, 100, 120, 150, 160& 170 L containers are manufactured.

CONTAINER VALVE

Features

  • Installed in the gas cylinder is used to control the release of agent.
  • Build up the container valve extinguishing kit together with cylinders
  • started by Solenoid Actuator, Manual Actuator or Pneumatic Actuator.
  • Container valve has long service life, low leakage rate, can automatically reset after use, re-filling agent needn’t change any accessories (such as burst disc, etc.).
  • The pressure gauge port of the container valve are available with connection thread of M10X1 or NPT1/8.

PENDENT & RECESSED PENDENT SPRINKLERS

Features

  • The bracket assembly consists of a nut and bolt, two bracket straps and one back channel.
  • To securely hold the container in position during the system discharge, two bracket assemblies are required per container.
  • Each strap is notched for insertion into the back channel allowing the container to be properly aligned.
  • The bracket assembly is designed to be mounted to a rigid vertical surface with the container assembly resting fully on the floor.

SAFETY RELIEF DEVICE

Features

  • • A burst disc is factory fitted to every container valve assembly.
  • • It is designed to rupture when the container becomes over pressurized when subjected to temperatures above the designed storage temperature of the container.

PRESSURE GAUGE

Features

  • Agent Pressure Gauge is installed on each extinguishing agent container valve, as a method of visually monitoring the internal pressure condition of the container assembly.

SAFETY VALVE

Features

  • The Safety Valve is installed in the Manifold; a burst disc is fitted to this valve.
  • When the internal pressure of the manifold exceeds the expected pressure, the safety disc will be broken quickly, then release the inside pressure.
  • The burst disc is designed to rupture when the manifold becomes over pressurized.

DISCHARGE PRESSURE SWITCH

Features

  • Feedback the information generated by the agent release pressure to tell the extinguishing control panel that system is opened, to indicate extinguishing agent released.
  • Wiring:
  • Remove the two screws retaining the cover and cover gasket.
  • A 1/2” NPT conduit connection is provided on the left hand side of theenclosure.
  • Two cast-in knockouts for the 1/2” conduit are located on the side and back of the enclosure. These can easily be knocked out by placing the blade of a screwdriver in the groove and tapping sharply with a hammer.
  • The three switch terminals are clearly labeled “common”, “normally open” and “normally closed”.
  • For switches supplied with lead wires, the following color coding applies:
  • Common-Yellow, Normally Closed-Orange, Normally Open-Brown.

PNEUMATIC/MANUAL ACTUATOR

Features

  • The actuator is installed on the container valve, is used to manually or pneumatically operate container valve.
  • The Pneumatic and Manual Actuator is used to manual mechanically or pneumatically operate the system at the container position and is fitted to the top of the valve assembly.
  • Pressure from a “Master” container or manual force is used to actuate the
  • valve.

ELECTRICAL ACTUATOR

Features

  • The removable Electrical Actuator locates to the top of the container valve.
  • 24 VDC is required for electrical operation.
  • Provision is made for the connection of a manual actuator to the top of theactuator assembly.
  • Due to the design of the bridge rectifier it will operate regardless of how it is wired up; the positive supply from control panel can be connected to either terminal 1 or 2 with the reverse for the negative supply.

MANUAL ACTUATOR

Features

  • The Manual Actuator is used to mechanically operate the system at the container position and is fitted to the top of the valve assembly.
  • Inadvertent operation is prevented by a safety pin which has to be removed
  • before releasing.

DISCHARGE HOSE

Features

  • Container installations may be connected to the system by means of a flexible discharge hose.
  • This enables containers to be disconnected for maintenance or recharge without dismantling other container mountings, manifold connections and pipe-work, etc.
  • The flexible discharge hose is provided with a swivel fitting at the inlet. Discharge hose is installed between container valve and check valve used to connect agent cylinder in a system, convenient installation and maintenance of
  • them.

PILOT HOSE MANIFOLD

Features

  • The pilot hose is used to connect pressure activated devices to the system, e.g. the master cylinder to the slave container to the pressure switch.

BLEED VALVE

Features

  • On manifold systems with connected reserves it is necessary to fit bleed valves at the location of the pneumatic actuator of the last slave container of both duty and reserve actuation lines.
  • Also a bleed valve is required to be fitted into the pilot line.
  • The bleed valve acts to relieve a gradual pressure buildup occurring perhaps as a result of a leaking container valve or check valve.
  • It also provides a means by which pressure trapped in the actuation line may be manually relieved.
  • The bleed valve relieves automatically up to a pressure of approximately 1.5 bar and seals at pressures above this.
  • Bleed valve is installed in the end of a closed pipeline, normal opened.
  • It is used to eliminate leakage gas due to accumulate in the pipeline, to prevent the system false starts, it will be closed, while inlet pressure up to setting point.After activation press the valve button, release the gas in the pipeline, then valve is reset.

DISCHARGE NOZZLE

Features

  • HFC-227ea is distributed within the protected area by the discharge nozzle which is sized to ensure the correct flow of agent for the risk.
  • Nozzles are available with 8 ports to allow for 180Æ or 360Æ horizontal dis-charge patterns.
  • Ports are drilled in special increments to the specified system design.
  • Discharge nozzles are installed in the end of pipeline hole size is calculated, discharge the gas uniformly, and satisfies the requirement of discharge time.

(+971) 4 210 2999

Give Us A Call

info@firehub.ae

Drop Us a Line

Bin Shabib Mall

Al Qusais - Dubai, UAE

Your Trusted Source for Firing Equipment – Reliable, durable solutions for all your firing needs

Subscribe Our Newsletter

Stay updated with our latest news, exclusive offers, and insights by subscribing to our newsletter. Join our community and never miss out on important updates and promotions.

Far east

ID 1349-785,

Crea Landmark 305

2-9 Reisenmachi, Hakata Ward

Fukuoka 8120039

JAPAN

U.S.A

900 Foulk Rd

Ste 201

Wilmington 

New Castle County 

Delaware 19803

United States of America (USA)

EUROPE

Gemini Business Park

Leeds LS7

3JB,UK

United Kingdom

MIDDLE EAST

SAUDI ARABIA

QATAR

OMAN

Kuwait

Bahrain

DISTRIBUTED BY

AWS DISTRIBUTION LLC

DUBAI, U.A.E

Copyright Firehub.ae © 2024. All rights reserved.